Heating Calculator
Work out the heat output your space needs, then request a quote for a suitable heater. Enter the room or enclosure size in metres.
Estimated heat output required
Kilowatts
—
kW
Watts
—
W
BTU / hour
—
BTU/hr
This is a guide for sizing portable or temporary heaters on site. It does not replace a full heating design. Factors such as open doors, high air change, very cold weather or poor seals can increase the output you need. Always allow a little spare capacity.
How we calculate it
Heat (W) = length × width × height × building factor × (temperature rise ÷ 20)
Building factors (watts per cubic metre at a 20°C rise):
- Brick/block with cavity wall — 35 W/m³
- Brick/block without cavity — 50 W/m³
- Timber / heavy plastic (marquee, tent) — 85 W/m³
1 kW = 1,000 W. BTU/hr ≈ watts × 3.412. Figures are a practical rule of thumb for UK site and temporary heating.